• Mechanical findings

• DCS findings

• VMS findings

• Analysis

• Conclusions

• Recomendations

• References

• Comments


Introduction

Advertisement 

The compressor was kept stopped for an investigation, which confirmed that an actual dry gas seal (DGS) failure had happened on the machine; dry gas seal rupture disk open, dry gas seal leak lines full with lube oil, compressor uncoupled and found not be able to rotate, etc.